MCP3422A7-E/MS - 18-Bit 2-Channel 240 SPS ADC | Microchip Technology
部品番号: MCP3422A7-E/MS ✓ 生産中MCP3422A7-E/MS 概要
An ADC is a data-conversion IC that transforms continuous analog voltage into a digital numerical code for processing, measurement, or control. The MCP3422 belongs to the delta-sigma ADC family, where an internal modulator and digital filter shape the conversion process. In the broader semiconductor hierarchy, the MCP3422 is an ADC, then an analog and mixed-signal IC, and finally a semiconductor used in embedded measurement and instrumentation systems.
The MCP3422A7-E/MS provides up to 18-bit resolution, two differential inputs, an onboard precision 2.048 V reference, and a differential input range of plus or minus 2.048 V. Its 240 SPS conversion rate is suitable for slow-changing process, sensor, and instrumentation signals rather than high-speed waveform acquisition. The two-channel architecture allows simultaneous monitoring of two related measurements or differential sensing of a bridge or transducer.
The converter uses an I2C-compatible two-wire interface to transfer conversion results and configure operating conditions. Its differential input structure helps reject common-mode noise when the sensor is connected through balanced wiring. The integrated reference reduces the number of external components needed for ratiometric or absolute measurements, although the application must account for reference accuracy, noise, and power-supply behavior.
Typical uses include industrial process monitoring, low-frequency sensor acquisition, pressure and temperature measurement, environmental instrumentation, and embedded data acquisition systems. For bridge-based sensors, the differential inputs can reject much of the excitation-signal noise present on both sensor lines. For slowly varying voltages, the 240 SPS rate provides sufficient conversion bandwidth while averaging noise through the converter's digital filtering.
PCB implementation should prioritize short, symmetric analog traces, a quiet ground return, and separation between the analog inputs and switching nodes. The datasheet pin-description table should be used when assigning connector and test points. Verify the selected gain, conversion timing, reference configuration, and digital pull-ups before committing the layout.
This product page combines the manufacturer's device description with package, application, comparison, and design guidance for engineers evaluating the MCP3422A7-E/MS in precision, low-speed measurement systems.
ドロップイン代替品: MCP3422A7-E/MS — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: MCP3422A7-E/MS (同一形状・フットプリント) — 相違点: Differential Input Range, Resolution, Input Channels, Sampling Rate, Package.
MCP3422A0-E/MS
✅ ドロップイン価格はお問い合わせください
データシートを見る →MCP3422A1-E/MS
✅ ドロップイン価格はお問い合わせください
データシートを見る →MCP3422A1T-E/MS
✅ ドロップイン📋 参考代替品(カタログ未掲載)
MCP3422A3-E/MS
✅ ドロップイン価格はお問い合わせください
データシートを見る →MCP3422A2-E/MS
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →MCP3422A7-E/MS 最大定格&電気的特性
| 分解能 | Up to 18 bits |
| Input Channels | 2 differential input channels |
| ADC Architecture | Delta-sigma |
| Conversion Rate | 240 SPS |
| Internal Reference Voltage | 2.048 V |
| Differential Input Range | +/-2.048 V differentially |
| Supply Voltage Range | 2.7 V to 5.5 V |
| Digital Interface | I2C, 2-wire |
| 動作温度範囲 | -40 C to +125 C |
| パッケージ | 8-MSOP |
| Device Type | Analog-to-digital converter |
| Input Configuration | Differential inputs |
| On-Board Reference | Yes, precision 2.048 V reference |
| Output Resolution | 18-bit |
| Number of Inputs | 2 |
| サンプリングレート | 240 samples per second |
MCP3422A7-E/MS 8-msop ピン配置ガイド
MCP3422A7-E/MS (8-msop パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: MCP3422A7-E/MS.
詳細は データシート をご参照ください。
主な用途
MCP3422A7-E/MS の用途: 6 件s: Industrial Process Monitoring, Temperature and Environmental Sensing, Bridge and Strain Measurement, Battery-Powered Environmental Instrumentation, Precision Data Acquisition, Power and Battery Monitoring.
Industrial Process Monitoring
The MCP3422A7-E/MS fits industrial process monitoring where sensors produce slowly changing voltages. Its 18-bit resolution and two differential channels allow a controller to measure two related process signals while rejecting common-mode disturbance. The 240 SPS conversion rate is appropriate for temperature, pressure, level, and flow transmitters that do not require waveform capture. The I2C interface reduces the number of host-controller connections, while the integrated 2.048 V reference simplifies scaling. Designers should isolate analog routing from motors, relays, and switching supplies, and should verify the selected gain and input range against the transmitter output.
おすすめ
Temperature and Environmental Sensing
The MCP3422A7-E/MS can acquire low-frequency temperature, humidity, and environmental sensor outputs in a compact embedded instrument. The two differential inputs are useful when one channel monitors a reference sensor and the other measures the target condition. Its up-to-18-bit resolution provides a high-resolution digital code, while the 240 SPS rate is more than sufficient for slow thermal changes. The integrated 2.048 V reference helps maintain consistent conversion scaling across both channels. Keep the sensor return path close to the analog ground reference and place filtering close to the device to prevent environmental noise from being sampled between conversions.
おすすめ
Bridge and Strain Measurement
The MCP3422A7-E/MS is suitable for bridge-based strain and pressure measurement because it provides two differential input channels and up to 18-bit resolution. A bridge output is small and commonly centered near a midpoint, so the ADC's differential architecture helps reject noise shared by both input lines. The 240 SPS rate supports static load, vibration-envelope, and slowly changing mechanical measurements. The integrated reference and I2C interface allow a compact instrumentation module to provide digital results without a separate reference controller. For best results, use symmetrical routing, a clean analog return, and appropriate input filtering while checking the sensor excitation requirements.
おすすめ
Battery-Powered Environmental Instrumentation
The MCP3422A7-E/MS can serve as the measurement front end in a battery-powered environmental node because its 2.7 V to 5.5 V supply range accommodates common embedded rails. The I2C interface allows the ADC to share a bus with a microcontroller or low-power sensor hub, reducing wiring and software complexity. Its 240 SPS rate suits periodic rather than continuous high-rate sampling, and the differential inputs help preserve measurement integrity in field wiring. The 8-MSOP package also supports compact PCB layouts. Power-management design should account for the ADC's operating current, input settling time, and the energy required for periodic sensor excitation.
おすすめ
Precision Data Acquisition
The MCP3422A7-E/MS is useful in precision data-acquisition systems that monitor two low-level, low-frequency signals. Its delta-sigma architecture, 18-bit resolution, differential inputs, and integrated 2.048 V reference are well aligned with laboratory and industrial measurements requiring stable digital output. The I2C interface provides a compact connection to a controller, while the 240 SPS limit makes the converter more suitable for temperature, position, and slow process variables than for oscilloscope-like waveforms. A careful analog layout, short input traces, and stable supply decoupling are essential to preserve the resolution promised by the converter.
おすすめ
Power and Battery Monitoring
The MCP3422A7-E/MS can measure differential battery-cell or power-rail voltages in a monitoring circuit. Its two channels support two monitored potentials or a differential measurement referenced to a common point. The 18-bit resolution can provide useful resolution for slowly changing supply conditions, and the internal 2.048 V reference simplifies calibration when the measured signal is scaled appropriately. The 240 SPS rate is sufficient for supervisory power measurements. However, high-voltage battery systems require external protection, attenuation, and isolation; the ADC itself is intended only for the specified 2.7 V to 5.5 V supply and input ranges.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: MCP3422A7-E/MS — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | MCP3422A0-E/MS | MCP3422A1-E/MS | MCP3422A1T-E/MS | MCP3422A3-E/MS |
|---|---|---|---|---|---|
| Package | 8-MSOP | 8-MSOP | 8-MSOP | 8-MSOP | 8-MSOP |
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Special Features | Integrated 2.048 V reference and differential inputs | MCP3422-family differential ADC | MCP3422-family differential ADC | MCP3422-family differential ADC | MCP3422-family differential ADC |
主な差別化要因
- 240 SPS conversion-rate option in an 18-bit two-channel ADC (vs MCP3422A1-E/MS)
- Differential two-channel measurement with integrated reference (vs MCP3422A0-E/MS)
- Same-footprint family alternative for PCB reuse (vs MCP3422A3-E/MS)
- I2C integration simplifies digital connections (vs MCP3422A1T-E/MS)
設計ノート
Route the two differential inputs as closely matched pairs and keep them away from switching nodes, relay contacts, and high-current return paths. Place input filtering and the ADC's supply bypass capacitors close to the relevant pins. A clean analog ground reference and short traces are especially important when using the converter's high-resolution modes.
The MCP3422A7-E/MS is intended for low-frequency, low-noise measurement rather than high-speed waveform capture. Keep sensor wiring short or use differential routing, establish a defined analog and digital grounding strategy, and validate the analog input bandwidth against the selected gain and conversion timing before adding external filters that could alter the measurement settling behavior.
The device operates from 2.7 V to 5.5 V, so the selected system rail must remain within that range including tolerance and transient excursions. Use local supply decoupling and verify that noise on the supply does not dominate the converter's noise performance. For battery-powered designs, account for the ADC's operating current and periodic-conversion duty cycle when estimating energy use.
Do not treat the 240 SPS maximum conversion rate as a general-purpose high-speed sampling capability. Confirm the selected gain, differential input range, conversion time, and I2C timing in the family datasheet. Also avoid assuming that the onboard 2.048 V reference makes external calibration unnecessary; offset, gain, reference accuracy, and PCB leakage can still affect the final measurement accuracy.
コンプライアンス情報
The device information identifies the MCP3422 family and its 8-MSOP packaging, but explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals declarations were not provided for this MPN.