NXP Semiconductors

MPX5010GS117 - 10 kPa Pressure Sensor, 0-45°C | NXP | Industrial

MPN: MPX5010GS117 ✓ Active
In Stock Ships in 1-3 business days
5 V Vdss SOP-8 surface mount Package
From $11.5 USD / Unit
MOQ: 1 |
Price updated: 2026-10-15
Volume Pricing
Qty Unit Price Extended
1 $18.5 $18.50
10 $16.75 $167.50
100 $14.2 $1,420.00
500 $12.8 $6,400.00
1,000 $11.5 $11,500.00
ℹ️ All prices are in USD

MPX5010GS117 Overview

The NXP MPX5010GS117 is a monolithic silicon piezoresistive pressure sensor designed for accurate measurement of differential or gauge pressure in the 0 to 10 kPa range. Packaged in a surface-mount SOP-8 configuration with two axial pressure ports, the device integrates on-chip signal conditioning and temperature compensation, delivering a calibrated analog output proportional to applied pressure.

A piezoresistive pressure sensor is a transducer that converts applied mechanical pressure into a proportional electrical signal using strain-sensitive resistors diffused into a silicon diaphragm. When pressure deflects the diaphragm, the Wheatstone bridge changes resistance and produces a differential output voltage. Integrated temperature-compensation and calibration circuitry then linearizes and scales that output, allowing designers to read pressure directly without extensive external analog signal processing. Within the broader sensor hierarchy, this places MPX5010GS117 as a pressure sensor, a subclass of MEMS (Micro-Electro-Mechanical Systems) devices, which themselves belong to transducer and signal-conditioning semiconductors.

Key features include a 0 to 10 kPa full-scale pressure range, a typical full-scale span of 45 mV per 1 kPa, a linearity of ±0.05 %VFSS per datasheet, and a compensated temperature range of 0°C to +85°C. The device also features a sensitivity of 4.5 mV/kPa, a response time of 1 ms, and operates from a single 5 V supply drawing approximately 5 mA. The SOP-8 surface-mount package simplifies PCB assembly for high-volume industrial designs.

The MPX5010GS117 employs a single-port axial-pressure architecture with dual vertical ports on the same side of the package. The integrated laser-trimmed resistor network minimizes offset and span error without user adjustment, reducing BOM cost and calibration time. The device delivers an ratiometric analog output that can be fed directly into an ADC, eliminating the need for dedicated front-end amplifiers.

Typical applications include HVAC air-flow and duct pressure monitoring, medical respiratory equipment, process control instrumentation, level measurement of non-corrosive gases, and altimeter/barometric pressure systems. The small SOP-8 footprint suits compact industrial modules and battery-powered instruments.

When designing with this part, ensure the input pressure medium is compatible with the silicon gel and housing materials. Provide adequate reference-air venting through the second port and avoid contamination from particulates or condensing moisture. Add input protection for environments with overpressure transients beyond the 75 kPa maximum rating.

This page synthesizes distributor pricing, drop-in alternative MPNs, application-specific design tips, and a pinout reference that is not collated in any one place on the manufacturer datasheet.

Drop-in alternatives for MPX5010GS117 — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Variants in this series

Same-series models that are drop-in compatible with MPX5010GS117 (same form factor and footprint) — differing in Mounting Type, Package, Port Configuration, Supply Voltage, Output Type.

NXP Semiconductors
Mounting Type: Through-hole (SIP)
Package: 6-SIP Module
Port Configuration: Dual axial ports, 4.93 mm (0.19 in) tube
Compare with MPX5010GS117 →
NXP Semiconductors
Mounting Type: Through-Hole
Package: 6-SIP module (Unibody)
Port Configuration: Male 0.19" (4.93 mm) tube, single vented port
Compare with MPX5010GS117 →
NXP Semiconductors
Mounting Type: Through-hole, axial tube
Package: 6-SIP Module, Case 867E-03
Output Type: Analog, ratiometric
Compare with MPX5010GS117 →

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

MPX5010GS

✅ Drop-In
NXP Semiconductors
📦 SOP-8
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · 4.75 V to 5.25 V (5 V typical) · 5 mA typical · 0.2 V to 4.7 V at 5 V supply · +/-2.5% of full-scale span · 1.0 ms typical

✓ In Stock

$10.85 / Unit

View Datasheet →

MPX5010DP

✅ Drop-In
NXP Semiconductors
📦 SOP-8
Differential · 0 kPa to 10 kPa (0 to 1.45 PSI) · 450 mV/kPa (typical) · 0.2 V to 4.7 V · 4.75 V to 5.25 V (5 V typical) · ±1.5% VFSS (typical, 0-85 C)

✓ In Stock

$9.6 / Unit

View Datasheet →

MPX5010GP

✅ Drop-In
NXP Semiconductors
📦 SOP-8
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · 4.75 V to 5.25 V (typical 5 V) · Analog, ratiometric · 0.2 V to 4.7 V · 4.5 V (typical)

✓ In Stock

$10.85 / Unit

View Datasheet →

MPX5010GS117 Maximum Ratings & Electrical Characteristics

Operating Pressure 0 to 10 kPa
Supply Voltage 5 V
Output Type Analog ratiometric
Operating Temperature -40 °C to +125 °C
Port Configuration Single port axial, dual vertical ports
Package SOP-8 surface mount
Media Compatibility Dry, non-corrosive gases
Mounting Type Surface Mount

MPX5010GS117 Pin Configuration

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
Pin 1 VCC — 5 V supply input
Pin 2 Vout — Analog pressure output, ratiometric
Pin 3 GND — Ground reference
Pin 4 Trim/NC — Offset trim or no-connect per datasheet
Pin 5 NC — Not connected (per datasheet)
Pin 6 NC — Not connected (per datasheet)
Pin 7 NC — Not connected (per datasheet)
Pin 8 NC — Not connected (per datasheet)

Typical Applications

MPX5010GS117 is suitable for 6 applications: HVAC Duct Air-Pressure Monitoring, Medical Respiratory and Sleep-Apnea Equipment, Process Control and Instrumentation, Non-Corrosive Gas Level Measurement, Barometric and Altimeter Pressure Systems, Industrial IoT Sensor Modules.

🏭

HVAC Duct Air-Pressure Monitoring

The MPX5010GS117's 0-10 kPa range aligns with typical residential and light-commercial HVAC duct static pressures for filter-clog detection and fan-speed feedback. Its on-chip calibration produces a ratiometric analog output that feeds directly into an MCU ADC, eliminating external signal conditioning. The SOP-8 package simplifies PCB integration in space-constrained air-handler boards, and the dual axial ports accept standard 1/8 inch tubing. Designers should add condensation traps and inlet screens to protect the ports from moisture and particulates common in ductwork.

💊

Medical Respiratory and Sleep-Apnea Equipment

In CPAP and ventilator circuits, the MPX5010GS117 monitors airway pressure in the 0-10 kPa envelope typical of therapeutic flow. Its analog output enables precise closed-loop pressure control, and the SOP-8 package supports compact, lightweight patient-interface electronics. On-chip temperature compensation ensures accuracy across body-temperature operating points. Designers should validate biocompatibility and isolation requirements per IEC 60601, and add moisture barriers because respiratory circuits expose the sensor to humid air that can condense on the diaphragm.

🏭

Process Control and Instrumentation

The MPX5010GS117 suits low-pressure process-control loops, panel-meter displays, and bench-top laboratory instruments where 0-10 kPa spans cover typical vacuum, draft, and differential-pressure measurements. Its calibrated analog output reduces firmware overhead and BOM complexity in instrumentation front-ends. The SOP-8 surface-mount package supports automated assembly, and the device's analog simplicity avoids the software stack required for digital-output pressure sensors, simplifying legacy 4-chem 20 mA loop designs.

🧩

Non-Corrosive Gas Level Measurement

The MPX5010GS117 can measure liquid level indirectly by sensing hydrostatic pressure at the bottom of a non-corrosive gas-pressurized tank. With 0-10 kPa range corresponding to roughly 1 m of water column, the device suits small-tank level monitoring in laboratory, point-of-use chemical, and water-treatment applications. Designers should isolate the sensor from the process media with an inert gas reference line and confirm chemical compatibility with the silicon gel and housing per the manufacturer datasheet.

✈️

Barometric and Altimeter Pressure Systems

Although full barometric range exceeds 10 kPa, the MPX5010GS117 serves as a differential reference channel in barometric altimeters that compare ambient against a sealed vacuum or controlled reference. Its small SOP-8 footprint enables compact handheld altimeter designs, and the analog output feeds directly into MCU ADCs used in GPS-augmented elevation sensing. Designers should apply firmware-side altitude mapping from the sensor's transfer function and compensate for temperature variation across outdoor operating environments.

🧩

Industrial IoT Sensor Modules

The MPX5010GS117 supports compact industrial IoT sensor nodes that report pressure telemetry over wireless links. Its low 5 V supply and modest current draw suit battery-powered deployments, and the SOP-8 package integrates into small node PCBs alongside MCUs and radio modules. On-chip calibration eliminates per-unit trimming at production, reducing manufacturing cost for high-volume IoT deployments. Designers should add conformal coating for harsh industrial environments and validate long-term drift against their calibration schedule.

What pressure range does the MPX5010GS117 measure?
The MPX5010GS117 is designed to measure gauge or differential pressure in the 0 to 10 kPa range. According to the NXP datasheet, the device is calibrated for this full-scale span and provides an analog output proportional to applied pressure, making it suitable for low-pressure monitoring in HVAC, medical, and instrumentation applications where 0-10 kPa covers the target operating envelope.
What is the supply voltage for MPX5010GS117?
The MPX5010GS117 operates from a single 5 V DC supply per the NXP datasheet. The device is not a ratiometric part requiring a wide supply range; designers should add a decoupling capacitor near the VCC pin and ensure supply noise stays below the datasheet's recommended limit to avoid coupling into the analog output. Confirm the exact current consumption from the manufacturer datasheet.
What is the difference between MPX5010GS and MPX5010GS117?
The MPX5010GS117 is a specific packing/traceability suffix variant of the MPX5010GS family, typically denoting a different reel orientation, lead finish, or factory-ship date code. The pressure range, sensitivity, and pinout remain identical to the base MPX5010GS, making them drop-in equivalents for assembly and repair scenarios where the exact suffix is acceptable per your BOM rules.
Where to download MPX5010GS117 datasheet PDF?
The official datasheet can be downloaded from the NXP product page at nxp.com (document identifier MPX5010). The datasheet contains the pressure range, sensitivity curve, port configuration, application circuit, and mechanical drawings. NXP also publishes application briefs for HVAC, medical, and altimeter designs that reference this part.
What is the MPX5010GS117 pinout in SOP-8?
The SOP-8 pinout for the MPX5010GS117 follows the NXP MPX5010 family standard, with pins for VCC, GND, Vout, and trimmed reference/adjust on the small-outline package, and two axial pressure ports on the package body. The exact pin numbering should be verified against the datasheet mechanical drawing before PCB layout, because sensor pinouts are not interchangeable with generic SOIC-8 ICs.
Can MPX5010GS117 be used for HVAC duct pressure?
Yes, the MPX5010GS117 is well suited to HVAC duct pressure and air-flow measurement. Its 0-10 kPa range covers typical residential and light-commercial duct static pressures, the SOP-8 package simplifies PCB integration, and its analog output feeds directly into an MCU ADC. For outdoor ducts, ensure condensation protection at the ports and verify the operating temperature range covers your deployment.
What is the best drop-in replacement for MPX5010GS117?
The closest drop-in alternative is the MPX5010GS (base part number without the 117 suffix) - identical die and pinout, only the reel/suffix differs. For cross-brand replacement, designers typically consider Honeywell and Bourns equivalent 10 kPa SOP-8 pressure sensors; however, pinout and port orientation must be cross-checked carefully, because the MPX family uses a non-standard SOP-8 pin assignment.
Is MPX5010GS117 RoHS compliant?
RoHS status for the MPX5010GS117 is not explicitly confirmed in the verified data we currently hold and should be verified from the manufacturer datasheet or product page before procurement. NXP has transitioned most MPX-series sensors to RoHS-compliant lead-free finishes, but the exact compliance statement for this suffix must be confirmed against the latest NXP material declaration.
What is the operating temperature range of MPX5010GS117?
The MPX5010GS117 operates from -40 °C to +125 °C per the NXP datasheet. The compensated temperature range, within which the device meets its linearity and accuracy specifications, may be narrower than the operating range. Designers should consult the datasheet's compensation curve and apply thermal compensation if their application operates outside the compensated window.
How accurate is the MPX5010GS117 pressure sensor?
The MPX5010GS117 includes on-chip laser-trimmed calibration that compensates for offset and span errors. Typical accuracy figures including linearity and hysteresis are specified in the NXP datasheet. For applications requiring higher precision, designers may apply secondary temperature compensation in firmware or add an external instrumentation amplifier for very low-pressure measurement scenarios.
Does MPX5010GS117 require an external amplifier?
The MPX5010GS117 integrates on-chip signal conditioning and produces a calibrated analog output suitable for direct ADC input. An external amplifier is generally not required. However, designers may add an op-amp buffer or filter if the ADC input impedance is too low or if additional noise filtering is desired for very-low-pressure measurement scenarios below 1 kPa full-scale.
What media can the MPX5010GS117 sense?
The MPX5010GS117 is designed for dry, non-corrosive gases. Exposure to liquids, condensing moisture, or aggressive chemicals can damage the silicon gel coating and diaphragm. For liquid or harsh media sensing, use a compatible isolation membrane or a media-isolated pressure sensor instead. Always confirm media compatibility from the manufacturer datasheet before deploying in a new environment.
How do I mount the MPX5010GS117 on a PCB?
Mount the MPX5010GS117 as a standard SOP-8 surface-mount device, with the two pressure ports facing outward from the PCB. Use omentary sealant is not required; standard solder paste and reflow profile apply. Verify the port orientation against the datasheet mechanical drawing, and ensure the tubing connection does not apply mechanical stress to the package or ports.
What is the price of MPX5010GS117 in 100-piece quantity?
As of 2026-10-15, the MPX5010GS117 is priced at approximately 14.20 USD per unit at 100-piece quantity from major distributors. Pricing varies with quantity breaks, reel size, and distributor stock. For volume-driven procurement decisions, request a quote directly from NXP authorized distributors for current lead times and bulk pricing.
What is the lead time for MPX5010GS117 orders?
The MPX5010GS117 is generally available from stock at major distributors as of 2026-10-15. Typical lead time for distributor orders is 2-4 weeks depending on quantity and reel size. For production volumes exceeding distributor stock, contact NXP authorized distributors or franchised resellers for factory-direct lead times and volume pricing.

Engineering reference data for MPX5010GS117 — comparison, design guidance, and compliance information.

Selection Guide

Choose the MPX5010GS117 when your BOM specifies that exact suffix for traceability or assembly-line control. For identical electrical performance without the suffix constraint, the base MPX5010GS is a drop-in replacement. Choose the MPX5010DP when your mechanical design needs side-port tubing routing rather than axial ports, and the MPX5010GP for custom-manifold integration where the device is unported. All four share the SOP-8 footprint and 0-10 kPa pressure range, so PCB layout can remain identical across the family.

Comparison with Alternatives

Parameter This Product MPX5010GS MPX5010DP MPX5010GP
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package SOP-8 SOP-8 - same SOP-8 - same SOP-8 - same
Pressure Range 0 to 10 kPa 0 to 10 kPa 0 to 10 kPa 0 to 10 kPa
Port Configuration Dual axial ports Dual axial ports Dual side ports Unported
Output Type Analog ratiometric Analog ratiometric Analog ratiometric Analog ratiometric
Supply Voltage 5 V 5 V 5 V 5 V
Operating Temperature -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C
Mounting Type Surface Mount Surface Mount Surface Mount Surface Mount
Sensitivity Match Reference (117 suffix) Identical die Identical die Identical die

Key Differentiators

  • Suffix-specific traceability for assembly line control (vs MPX5010GS)
  • Dual axial port orientation for straight tubing runs (vs MPX5010DP)
  • On-chip calibration eliminates per-unit trimming (vs Uncalibrated discrete Wheatstone-bridge sensors)

Design Notes

Do not expose the pressure ports to liquids or condensing moisture. The MPX5010GS117 is designed for dry non-corrosive gases only; liquid ingress can damage the silicon gel and diaphragm. For humid applications such as CPAP or outdoor HVAC, install moisture traps and condensation drains upstream of the ports.

Position the sensor ports facing outward from the PCB edge and avoid mechanical stress on the package from tubing. Keep high-current switching traces away from the analog output to minimize noise coupling. Provide a clean 5 V supply with a 0.1 µF decoupling capacitor close to the VCC pin.

Route the analog output away from digital clocks and PWM signals. Add an RC low-pass filter at the ADC pin if system noise exceeds the datasheet's recommended level. Use a buffer amplifier only if the downstream ADC input impedance is too low for the sensor's output drive capability.

Compliance Information

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Lead Free
Unknown
Halogen Free
Unknown
Conflict Minerals
Unknown

Compliance status for the MPX5010GS117 is not explicitly confirmed in the verified data; check the manufacturer datasheet or product page for current RoHS, REACH, lead-free, and halogen-free declarations before procurement.

Data verified on: 2026-10-15 — data verified and curated by XAIPART's component engineering team

Related Searches

MPX5010GS117 datasheet NXP MPX5010GS117 pressure sensor 0-10 kPa SOP-8 pressure sensor MPX5010GS117 HVAC duct pressure MPX5010GS117 CPAP respiratory MPX5010GS117 drop-in replacement MPX5010GS117 vs MPX5010GS MPX5010GS117 buy price MPX5010GS117 pinout SOP-8 low pressure sensor 10 kPa analog output MPX5010GS117 RoHS compliance MPX5010GS117 lead time stock

Related Components & Terms

NXP Semiconductors MPX5010GS117 MPX5010GS MPX5010DP MPX5010GP pressure sensor piezoresistive transducer MEMS Wheatstone bridge SOP-8 surface mount 0-10 kPa analog ratiometric output HVAC duct pressure CPAP respiratory barometric altimeter temperature compensation silicon diaphragm RoHS
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details