Texas Instruments

TIOL221RGER - Dual IO-Link PHY with LDO & SPI | TI

料号: TIOL221RGER ✓ 量产中
有现货 1-3 个工作日内发货
>= 500 mA (sink or source) Id 24-VQFN (4x4 mm), VQFN-24 (RGE) Package
联系我们 询价
最小起订量: 1 |
价格更新于: 2026-08-30
批量定价
数量 单价 小计
1 $0 $0.00
10 $0 $0.00
100 $0 $0.00
500 $0 $0.00
1,000 $0 $0.00
ℹ️ 所有价格均以 USD 计价

TIOL221RGER 概述

The Texas Instruments TIOL221 (TIOL221RGER) is a dual-channel IO-Link device physical layer (PHY) transceiver with an integrated LDO and SPI interface, supplied in a 24-pin VQFN (4x4 mm) package. It serves as the complete physical layer between an IO-Link master and a remote sensor or actuator node over the three-wire IO-Link interface (L+, L-, CQ).

An IO-Link PHY (physical layer transceiver) is a specialized industrial communication interface IC that handles line driving, wake-up detection, and protection for point-to-point digital communication networks. Within the system hierarchy, it sits below the microcontroller (logic layer) and above the physical cabling, forming part of the broader industrial networking and sensor interface semiconductor category.

Key features include dual CQ channels with integrated low-power output drivers featuring active reverse polarity protection, wake-up pulse generation and detection (sinking or sourcing >= 500 mA for a typical 80 us duration per IO-Link specification), and wake-up reporting to the local microcontroller by asserting the WU pin low. Internal protection covers undervoltage, overcurrent, and overtemperature conditions, with fault reporting to the host.

The integrated LDO reduces external BOM count, and the SPI interface allows flexible configuration and diagnostics. The device can also be configured to generate wake-up pulses and be used in IO-Link master applications, and it integrates an auxiliary DI (digital input) channel.

Typical applications include IO-Link sensor hubs, industrial proximity sensors, actuator nodes, and compact IO-Link master ports.

Design tip: ensure the CQ driver thermal budget accounts for wake-up pulse current, and use the fault reporting pins for system-level diagnostics.

直接替换替代料: TIOL221RGER ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

快速对比工具——选择替代料号进行并排对比:

TIOL221RGERT

✅ 直接替换 ⚠️ 规格未核验
📦 24-VQFN (4x4)
identical die, tape-and-reel ordering code variant

📋 参考替代料(不在目录中)

ℹ️ 3 个跨封装料号已隐藏——不同封装需要 PCB 改动,并非真正的直接替换。 联系我们 如果您需要跨封装建议。

TIOL221RGER 规格参数

功能 Dual Channel IO-Link Device PHY with Integrated LDO and SPI
通道数 2 CQ channels + 1 auxiliary DI
接口 SPI + IO-Link 3-wire (L+, L-, CQ)
Wake-up Pulse Current >= 500 mA (sink or source)
Wake-up Duration Typically 80 us
Wake-up Reporting WU pin asserted low for tWUL
Protection Features Undervoltage, overcurrent, overtemperature, reverse polarity (active)
Integrated LDO Yes
Output Drivers Dual low-power with active reverse polarity protection
IO-Link Mode Device PHY; also configurable for IO-Link master wake-up generation
封装 24-VQFN (4x4 mm), VQFN-24 (RGE)
安装类型 Surface Mount
Fault Reporting Yes (UV, OC, OT)

TIOL221RGER 24-vqfn (4x4 mm), vqfn-24 (rge) 引脚配置指南

TIOL221RGER(24-vqfn (4x4 mm), vqfn-24 (rge) 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。

TIOL221RGER 的 24-vqfn (4x4 mm), vqfn-24 (rge) 封装引脚图

暂无详细引脚数据: TIOL221RGER.

请参阅 数据手册 以查看完整引脚配置。

典型应用

TIOL221RGER 适用于 6 应用s: IO-Link Sensor Hubs, Industrial Proximity Sensor Nodes, IO-Link Master Ports, Actuator Nodes and Valve Control, Factory Automation PLC I/O Modules, Prototyping and IO-Link Evaluation.

🏭

IO-Link Sensor Hubs

The TIOL221's dual CQ channels let one IC connect two IO-Link sensor ports, making it ideal for sensor hub nodes that aggregate multiple binary or analog sensors. Its integrated LDO and SPI reduce BOM count, while >= 500 mA wake-up pulse capability and WU pin reporting ensure full IO-Link wake-up compliance. Reverse polarity and overcurrent protection tolerate industrial field miswiring, and the auxiliary DI channel adds a bonus digital input without extra transceivers.

🔧

Industrial Proximity Sensor Nodes

For IO-Link proximity and photoelectric sensors, the TIOL221 acts as the complete physical layer over the three-wire interface. The 80 us, >= 500 mA wake-up pulse handling meets IO-Link specification timing, and fault reporting for undervoltage, overcurrent, and overtemperature enables smart diagnostics demanded by IO-Link Class A ports. The 4x4 mm VQFN-24 fits the compact housings typical of modern industrial sensors.

🌐

IO-Link Master Ports

The TIOL221 can be configured to generate wake-up pulses, per TI's product page, which is exactly what an IO-Link master port needs to activate sleeping device nodes. Dual channels allow one IC to serve two master ports or one port plus an auxiliary DI. Integrated drivers with active reverse polarity protection improve master port robustness against wiring faults, and SPI enables master-side configuration and diagnostics.

⚙️

Actuator Nodes and Valve Control

In IO-Link actuator nodes (solenoid valves, indicator drives), the TIOL221's dual CQ low-power drivers with active reverse polarity protection switch loads under host SPI control. Overcurrent and overtemperature protection guard against stalled loads and shorted wiring, while the auxiliary DI channel can read local feedback such as limit switches. The integrated LDO supplies local logic, simplifying compact actuator PCB designs.

🖥️

Factory Automation PLC I/O Modules

PLC remote I/O modules benefit from the TIOL221's channel density: two CQ ports plus a DI channel in a single 4x4 mm VQFN-24 reduces board area versus discrete transceivers. SPI-based configuration lets firmware adapt port behavior at runtime, and fault reporting supports predictive-maintenance diagnostics over the IO-Link backbone. Wake-up detection with WU pin signaling simplifies power-saving node designs.

🧩

Prototyping and IO-Link Evaluation

The TI TIOL221EVM evaluation module lets engineers exercise device and master wake-up configurations, SPI register settings, and protection behaviors before committing to a PCB. Since the EVM ships from DigiKey as of 2026-08-30, teams can validate wake-up timing (80 us, >= 500 mA) and tWUL signaling against a master in days rather than weeks, de-risking the transition to production firmware.

What is the TIOL221?
The TIOL221 is a Texas Instruments dual-channel IO-Link device physical layer (PHY) transceiver with an integrated LDO and SPI interface. It acts as the complete physical layer between an IO-Link master and a remote node over the three-wire interface, integrating dual CQ drivers with reverse polarity protection plus an auxiliary DI channel. Source: TI datasheet TIOL221 (54 pages, ti.com/lit/gpn/TIOL221).
What package does TIOL221RGER come in?
The TIOL221RGER is supplied in a 24-pin VQFN (RGE) package measuring 4x4 mm. According to DigiKey, it is listed as a 2/2 half-duplex I/O-Link transceiver in 24-VQFN (4x4). The VQFN-24 belongs to the QFN surface-mount package family, suitable for compact industrial sensor and actuator nodes.
How does TIOL221 handle wake-up pulses?
The TIOL221 can generate and detect IO-Link wake-up pulses. Per the TI datasheet, the device sinks or sources at least 500 mA for the wake-up duration (typically 80 us) depending on the CQ logic level, per the IO-Link specification. Upon detecting a wake-up condition, it communicates to the local microcontroller by asserting the WU pin low for the duration of tWUL.
Is TIOL221 suitable for IO-Link master applications?
Yes. According to TI's product page, the TIOL221 can be configured to generate wake-up pulses and can be used in IO-Link master applications, in addition to its primary role as an IO-Link device PHY. This flexibility lets one IC cover both master port wake-up generation and device-side transceiver duties in industrial designs.
What protection features does the TIOL221 integrate?
The TIOL221 integrates undervoltage, overcurrent, and overtemperature protection with fault reporting to the host, plus active reverse polarity protection on its dual low-power output drivers. According to TI's product page, these internal protection functions reduce external component count and improve robustness in industrial field-wiring environments where miswiring is common.
Where can I buy TIOL221RGER and what is the price?
The TIOL221RGER can be purchased from authorized distributors including DigiKey and Mouser, which list the part as in stock and shipping today. As of 2026-08-30, exact tier pricing was not captured in the verified data - check the DigiKey or Mouser product pages (TIOL221RGER) for current pricing and quantity breaks.
What is the difference between TIOL221 and TIOL1115?
The TIOL221 is a dual-channel IO-Link device PHY with integrated LDO and SPI, while the TIOL1115 is a single-channel IO-Link device transceiver. Both target IO-Link device nodes, but the TIOL221 doubles channel density in one VQFN-24 package and adds an SPI interface and LDO, suiting sensor hubs; the TIOL1115 suits simpler single-port nodes.
Is TIOL221 the same as TIOL1113?
No. The TIOL1113 is a single-channel IO-Link PHY from TI, whereas the TIOL221 integrates two CQ channels, an auxiliary DI channel, an LDO, and SPI in a 24-VQFN (4x4). The TIOL221 suits multi-sensor IO-Link hubs; the TIOL1113 suits single-channel device designs. They are functionally related but not drop-in interchangeable.
What is the best drop-in replacement for TIOL221?
There is currently no verified true drop-in (pin-to-pin, same-package) replacement for the TIOL221 in the VQFN-24 (RGE) package. The closest same-family options are TI's single-channel TIOL1113/TIOL1115 and ST's L6360, but each requires pinout and footprint review before use. Confirm alternatives against the TIOL221 datasheet pinout before production.
Is there an ST equivalent for TIOL221?
STMicroelectronics offers the L6360, an IO-Link device transceiver with integrated DC-DC and protections, as the closest cross-brand functional equivalent. However, it is not pin-compatible with the TIOL221's 24-VQFN (4x4) footprint, so PCB redesign is required. Evaluate the L6360 datasheet against TIOL221 specifications before substituting.
When should I choose TIOL221 over single-channel IO-Link PHYs?
Choose the TIOL221 when your node has two CQ ports (sensor hub, dual actuator) and you want integration: dual drivers, an auxiliary DI, an LDO, and SPI configuration in one 4x4 mm VQFN-24. For single-port nodes where dual channels add cost, a single-channel TIOL1113/TIOL1115 is more economical.
Where can I download the TIOL221 datasheet PDF?
The official TIOL221 datasheet PDF is available from Texas Instruments at https://www.ti.com/lit/ds/symlink/tiol221.pdf (also reachable via ti.com/lit/gpn/TIOL221). The document is 54 pages and covers electrical characteristics, the SPI register map, wake-up timing (tWUL), protection behavior, and application circuits.
Does TI have an evaluation board for the TIOL221?
Yes, the TIOL221EVM is TI's official evaluation module for the TIOL221 IO-Link interface transceiver. It is available from DigiKey (listed as ships today as of 2026-08-30) and enables rapid prototyping of IO-Link device or master wake-up configurations without designing a custom PCB.
What are the key specifications of TIOL221 that engineers should know?
Key TIOL221 specifications: dual-channel IO-Link device PHY with integrated LDO and SPI; wake-up pulse sink/source >= 500 mA for typically 80 us per IO-Link specification; WU pin output (asserted low for tWUL) for wake-up reporting; undervoltage, overcurrent, and overtemperature protection with fault reporting; active reverse polarity protection on dual output drivers; auxiliary DI channel; 24-VQFN (4x4 mm) package. Source: TI datasheet TIOL221.

工程参考数据: TIOL221RGER ——对比、设计指导和合规信息。

选型指南

Choose the TIOL221 when your IO-Link node needs two CQ ports, an auxiliary DI, an integrated LDO, and SPI-based configuration in one compact 24-VQFN (4x4 mm) package - typical of sensor hubs, dual-port master designs, and smart actuator nodes. Choose TI's single-channel TIOL1113 or TIOL1115 when only one IO-Link port is required and pin-configuration (no SPI) is acceptable; these reduce cost for simple device nodes. Choose ST's L6360 if you need an integrated buck converter and an ST supply chain, accepting a different package and pinout. There is no verified pin-to-pin drop-in replacement for the TIOL221 in its VQFN-24 footprint, so evaluate any substitute at PCB level with the TI datasheet (54 pages) in hand.

与替代料对比

参数 本产品 TIOL1115DGQR TIOL1113DMRR L6360
Package 24-VQFN (4x4 mm, RGE) VSSOP-10 SOIC-8 QFN-32
Brand Texas Instruments Texas Instruments Texas Instruments STMicroelectronics
CQ Channels 2 1 1 1 (plus DI/DO)
SPI Interface Yes No (pin-configurable) No (pin-configurable) Yes
Integrated LDO Yes Yes (LDO integrated) Yes (LDO integrated) Integrated DC-DC (buck)
Wake-up Pulse Capability Generate and detect, >= 500 mA / 80 us IO-Link device wake-up detect IO-Link device wake-up detect IO-Link wake-up detect
Protection UV, OC, OT, reverse polarity (active) UV, OC, OT, reverse polarity UV, OC, OT, reverse polarity UV, OC, OT, thermal

关键差异点

  • Dual CQ channels in one 4x4 mm package (对比 TIOL1115DGQR)
  • SPI-configurable operation (对比 TIOL1113DMRR)
  • Auxiliary DI channel (对比 L6360)

设计说明

The TIOL221 integrates an LDO, but the CQ drivers must sink or source >= 500 mA during each ~80 us wake-up pulse. Size the VQFN-24 exposed pad and PCB copper for these transient currents, and verify the upstream supply does not droop below undervoltage thresholds during wake-up, which could trigger false fault reporting.

Place the L+ and CQ line protection and bulk capacitance close to the IC and use short, wide traces for the CQ channels. Connect the thermal pad to a solid ground plane with multiple vias to dissipate wake-up pulse energy and improve overtemperature protection accuracy.

Wake-up timing is IO-Link-specified (typically 80 us at >= 500 mA) and the WU pin asserts low only for tWUL - ensure the MCU polls or uses an interrupt on WU rather than level-holding assumptions. When configuring via SPI, confirm register defaults match your CQ mode before enabling drivers to avoid unintended wake-up pulse generation.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

Compliance status not stated in verified web data; consult TI product page and datasheet for RoHS/REACH details.

数据核验日期: 2026-08-30 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

TIOL221 datasheet TIOL221RGER price Texas Instruments TIOL221 IO-Link transceiver dual channel IO-Link PHY with LDO and SPI 24-VQFN IO-Link transceiver TIOL221 vs TIOL1115 TIOL221 drop-in replacement IO-Link sensor hub transceiver IC IO-Link master wake-up pulse generator IC ST equivalent to TIOL221 TIOL221EVM evaluation board buy what is IO-Link wake-up pulse current requirement

相关元器件 & 术语

Texas Instruments TIOL221 TIOL221RGER TIOL1115 TIOL1113 TIOL221EVM STMicroelectronics L6360 IO-Link IO-Link PHY physical layer transceiver SPI LDO VQFN-24 QFN family wake-up pulse undervoltage protection overcurrent protection overtemperature protection reverse polarity protection DigiKey Mouser industrial automation sensor hub
相关技术指南
TIOL221RGER 双通道 IO-Link PHY:完整技术指南、规格与采购指南(2026)
TIOL221RGER:TI 双通道 IO-Link PHY,集成 LDO、SPI,唤醒电流 ≥500 mA,1.2 kV 浪涌(IEC 61000-4-5),24-VQFN 4x4 mm。截至 2026-09-02 现货。
8 分钟阅读
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情