LM393ADGKR - Dual 36V Comparator | Texas Instruments
MPN: LM393ADGKR ✓ 啟用中LM393ADGKR 概覽
A differential comparator is an analog integrated circuit that evaluates the voltage difference between its inverting and non-inverting inputs. The LM393ADGKR belongs to the comparator and amplifier IC hierarchy within broader semiconductor and signal-conditioning applications. Its two channels operate independently, while a common supply and ground establish the operating reference for both comparators.
Key characteristics include a 2 mV input offset voltage, 250 nA input bias current, a 1.3 us response time, and an open-collector output configuration. The common-mode input range includes ground, supporting interfaces where one signal approaches the lower supply rail. Open-collector outputs can sink useful current and require an external pull-up resistor, enabling wired logic, level translation, and flexible output rise-time control.
The LM393ADGKR accepts single-supply operation across a broad voltage range, while dual-supply applications can use the available ±18 V operating range identified for this device. Because the output stage is open collector, the output voltage is set by the pull-up network rather than actively driven high. This architecture is efficient for alarm, relay-control, and interface circuits, but it also means the output cannot source current without suitable external circuitry.
Typical applications include industrial threshold detection, battery and power-supply monitoring, sensor conditioning, window comparison, and open-drain logic interfacing. The dual-channel configuration reduces component count when two independent comparisons are needed. It is also appropriate for systems that intentionally require a pull-up-defined high level, such as wired interconnects, indicator drivers, and level-shifting arrangements.
The principal design consideration is the open-collector output. Select a pull-up resistor that provides adequate sink current while keeping rise time within the system timing budget. Also verify input common-mode limits, supply sequencing, output leakage, and thermal conditions for the exact operating environment before finalizing the circuit.
This page consolidates electrical characteristics, verified lifecycle and compliance information, pin-compatible replacement options, and practical design guidance for engineers evaluating the LM393ADGKR in industrial, monitoring, and general-purpose comparator circuits.
直接替換替代品,適用於 LM393ADGKR — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: LM393ADGKR (相同外形與佔位) — 差異在於 Comparator Type, Number of Channels, Output Type, Package.
LM393BIDGKR
✅ 直接替換聯絡詢價
查看資料表 →LM293ADGKR
✅ 直接替換📋 參考替代品(不在目錄中)
LM393ADGKR 最大額定值與電氣特性
| Comparator Type | Dual differential comparator |
| Number of Channels | 2 channels |
| 輸出類型 | Open-collector |
| Supply Voltage Range | 2 V to 36 V |
| Dual Supply Voltage Range | ±1 V to ±18 V |
| Response Time | 1.3 us |
| Input Offset Voltage | 2 mV |
| Input Bias Current | 250 nA |
| Common-Mode Input Range | Includes ground |
| Input Type | Rail-to-Rail |
| 封裝 | 8-pin VSSOP |
| 安裝類型 | Surface mount |
| Device Grade | Industrial grade |
| 生命週期狀態 | Active |
| RoHS Compliance | Compliant |
| REACH Compliance | Unknown |
| AEC-Q100 Qualification | Not qualified |
LM393ADGKR 8-pin vssop 腳位配置指南
LM393ADGKR(8-pin vssop 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: LM393ADGKR.
請參閱 資料表 以查看完整腳位配置。
典型應用
LM393ADGKR 適用於 6 應用s: Industrial Threshold Detection, Power-Supply Monitoring, Battery Voltage Supervision, Sensor Signal Conditioning, Window Comparison, Open-Drain Interface Circuit.
Industrial Threshold Detection
The LM393ADGKR fits industrial threshold detection because its two independent channels compare input voltages with a 2 mV input offset and 1.3 us response time. Place one signal on each comparator input and use the open-collector output to drive an alarm, relay, or digital input. The common-mode range includes ground, which is useful when monitoring low-level process or sensor signals. A pull-up resistor establishes the inactive logic level and should be selected from the required sink current and maximum transition-time constraints.
推薦
Power-Supply Monitoring
The LM393ADGKR can monitor a power rail by comparing its voltage against a reference-derived threshold. Its 2 V to 36 V single-supply capability covers a broad range of industrial and embedded supply levels, while the open-collector output can directly alert a system controller. The two channels permit monitoring of a supply and its associated signal simultaneously. Account for input offset tolerance, reference accuracy, and the pull-up voltage when setting the system trip point.
推薦
Battery Voltage Supervision
The LM393ADGKR is appropriate for battery supervision when an early warning or undervoltage event must trigger a discrete control action. Its low 250 nA input bias current helps reduce measurement disturbance, and the 1.3 us response time allows rapid transition during threshold crossing. The open-collector output can pull a supervisor line low or drive an indicator through a pull-up. Select the external reference and resistor divider carefully so battery chemistry, tolerance, and temperature do not create false trips.
推薦
Sensor Signal Conditioning
The LM393ADGKR converts an analog sensor level into a logic decision when used as a threshold comparator. The differential inputs allow a sensor signal to be compared with a reference, and the 2 mV offset is useful when the decision boundary is close to the measured level. The common-mode range includes ground, supporting sensors whose output approaches the lower rail. For slow sensor signals, account for noise around the threshold and add filtering before the comparator when excessive output toggling is observed.
推薦
Window Comparison
The LM393ADGKR supports window comparison by assigning its two independent channels to the lower and upper limits of an acceptable signal range. The two 1.3 us channels allow both boundaries to be evaluated, while their open-collector outputs can be combined through suitable pull-ups and logic. This arrangement is useful for validating supply levels, signal ranges, or sensor limits. Review output-state conventions carefully when combining the channels, and confirm that the common-mode range covers both threshold voltages.
推薦
Open-Drain Interface Circuit
The LM393ADGKR's open-collector outputs make it useful for wired open-drain interfaces, status buses, and level translation. Each output can pull a logic node toward ground while an external pull-up connects that node to the desired supply voltage. With a 1.3 us response time, the device suits general-purpose control and alarm signals rather than very high-speed data channels. Select the pull-up voltage for the receiving device, check output leakage during the high state, and include the receiver input current in the resistor calculation.
推薦
推薦產品摘要
工程參考資料,適用於 LM393ADGKR — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | LM393BIDGKR | LM293ADGKR | LM393DGKR |
|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | VSSOP-8 (DGK) | VSSOP-8 (DGK) | VSSOP-8 (DGK) | VSSOP-8 (DGK) |
| Comparator Channels | 2 channels | 2 channels | 2 channels | 2 channels |
| Output Type | Open-collector | Open-collector | Open-collector | Open-collector |
| Automotive Qualification | Not qualified | Not qualified | Not qualified | Not qualified |
主要差異化特點
- Lower offset and bias currents in the B-version upgrade (對比LM393BIDGKR)
- Faster family-member response time (對比LM393BIDGKR)
- Higher maximum operating-voltage rating (對比LM393BIDGKR)
設計說明
Do not treat the open-collector output as a push-pull logic output. Every output node needs an external pull-up resistor unless another open-drain device or pull-up network already provides one. Select the resistor so that the low-state sink current remains within the device rating while the high-state rise time meets the circuit timing requirement. Include every receiver input current and output leakage path in the high-level calculation.
Keep the common-mode input voltages inside the specified operating range, which includes ground but does not imply unlimited rail-to-rail input capability. This matters near the upper supply rail and when the comparator is used with ±18 V dual supplies. The 2 mV input offset also contributes directly to the switching threshold, so resistor and reference tolerances should be included when defining a precision trip point.
Route the two comparator channels with attention to nearby switching nodes because differential input traces can pick up coupled noise. Keep the input and pull-up connections short, place the pull-up resistor close to the output node, and maintain separation from high-current or high-voltage switching paths. For sensitive threshold measurements, ground the input-referenced circuitry carefully and evaluate filtering without adding excessive delay to the 1.3 us response target.
The comparator is normally used in a low-power signal-conditioning role, but actual dissipation and junction temperature depend on the exact device limits, supply voltage, output duty cycle, and ambient environment. Verify these conditions against the manufacturer operating and absolute-maximum ratings. Because the VSSOP package has limited heat-spreading area, avoid placing the device next to a high-dissipation regulator without reviewing the PCB thermal path.
合規資訊
RoHS compliance is identified in the component listing. REACH, lead-free status, halogen-free status, and conflict-minerals status are not confirmed by the manufacturer documentation used for this page. The LM393A is identified as an industrial-grade device.